Eberspacher Airtronic fault finding guide, follow the trouble shooting steps detailed to diagnose the common faults for all eberspacher airtronic models

 

Our staff are trained by Eberspacher in all aspects of both fitting and repair.

With over 8 years experience, and thouands of hours hands on experienece.

PF Jones are able to handle any eberspacher inquiry speedly and promptly

We have over 3000 eberpacher parts on the shelves.

Including Airtronic and Hydronic Units

TROUBLESHOOTING FOR Eberspacher AIRTRONIC D2/D4/D5 HEATERS

View our range of Eberspacher Airtronic Heaters

If you are looking for the eberspacher fault codes they can be found at Eberspacher Fault Codes

 

TROUBLESHOOTING FOR AIRTRONIC D2/D4/D5 HEATERS
(“No start” and “Heater Stops” conditions)

Use these recommendations in conjunction with Fault Code List and heater’s manual

Description of the problem

  Possible reason and method of repair*
     
Absolutely nothing happens when the heater is turned on   1. Check voltage on heater’s harness on the heater’s side (pin # 1 and 10 on Airtronic connector). Turn the heater ON and make sure that the voltage is still OK. Repair harness and connections if necessary.
     
    2. If the voltage is OK, than try to start the heater by connecting together red and yellow wires on control branch of the heater’s harness. Make sure that you have +12 or +24 volts on the red wire on the control branch
     
    3. If the voltage is OK but the heater still does not start even if red and yellow wires are connected to each other, then the most likely ECU is locked, bad, or one of the startup self tests fails
    Use Diagnostic tool to retrieve fault codes from heater’s memory and unlock ECU is it is locked.  Follow heater’s manual for the fault codes description and repair methods
     
Being turned on, heater turns blower a few times, FMP and ECU’s relay may click one time but heater would not make an attempt to start  

1. Bad electrical connections. Check voltage like described in case #1

2. Start-up self test failed. Retrieve fault codes from heater’s memory using Diagnostic tool or EDiTH, refer to the heater’s manual for the description and repair methods
     
Heater switches into shut-down phase 20-25 seconds after being turned on (the most likely, fault code 11 found in memory)   Check voltage on heater’s harness on the heater’s side (pins 1 and 10 on Airtronic connector). Turn the heater ON and make sure that the voltage is still OK. Repair harness and connections if necessary.
     
Being turned on, heater just blows cold air, never stops and never performs a start attempt. No fault code recorded.  
  • Was “Ventilation” button pressed instead of “Heat”?
  • Replace combo Sensor
  • Replace ECU if necessary
     
Heater makes two attempts tostart with no success and then stops completely. No smoke comes from the exhaust pipe, some smoke can be seen between the exhaust pipe and heat exchanger.  

Reroute it if this is the case for not having it to be U-shaped

2. Check combustion air intake pipe. If the exhaust and combustion air intake pipes are OK, see case #6 below
     
Heater makes two attempts to start, may smoke for a while and then it stops  

1. Do the fuel quantity check, if the amount of fuel is insufficient, than check the fuel pick-up pipe, fuel lines and connections, fuel filter on the pump, replace the filter or pump if necessary.

2. Check the glow pin, clean ventilation hole and replace atomizing screen.

3. If necessary, take the heater apart, clean combustion tube (including it’s all air ways) and the heat exchanger
     
Heater makes two attempts to start, then stops. Both times it sounds like the ignition takes place and then combustion process stops together with the fuel metering pump. Usually no smoke comes from the exhaust pipe just like when the heater starts normally  

1. The heater ignited but the flame was not detected. Check and replace combo sensor.

2. Replace ECU if combo sensor was good.
     
Heater ignites normally, goes into boost mode, then switches to stand-by mode, blower is slowly spinning but the heater never restarts. No fault code recorded.  

1. Using EDiTH, check setpoint for temperature and current air temperature. Replace part which works improperly. Swap minicontroller if do not have EDiTH;

2. If minicontroller OK, install external temperature sensor or replace ECU
     
Heater ignites normally, but often stops (codes 52-56 found in memory)  

1. Check fuel lines for gaps in connections inside connection pieces

2. If the heater stops only when the vehicle is in motion, reroute combustion air intake and exhaust pipes, or bend their ends toward to the rear of the vehicle

   *To avoid inefficient expenses, it is strongly recommended to have the heater diagnosed by specialist before replacing expensive parts

 

More information on Eberspacher Heating Systems

Comments

good evening,

we have just had a d2 airtronic fitted to our motorhome.We have now needed to use it and all it does is click alot blow cold air and then close down.
please can you advise

Hi

A couple of things to check - Battery voltage as it needs to be at 12v + so that it can start. Easiest way of checking this it to put the battery on charge then try to start it whilst it is on charge.
Also depending on the modulator / timer you have to operate the heater there should be a fault code on the display that will give an indication to the error
I have a new van with an airtronic 2 press start button and it says on the fan comes on for several minutes then shuts down, we have two fault codes showing fault 51, fault 52 can you offer a possible solution as technician spent 4 hours yesterday no result regards Alan.

051 Faulty flame recognition At start, if flame sensor is a above 70°C > 240 seconds; check
exhaust gas and combustion air supply, check flame sensor,
replace if necessary.
052 No start safety time exceeded No flame detected on start attempt.
Check fuel delivery and fuel supply, Check exhaust gas
and combustion air ducts
I have a airtronic d4 with the none diagnostic 701 7
day timer. After fuel supply problems(
now fixed) d4 completelt dead. Power to all parts but no life. Presumably ecu is locked.
How can i unlock, please?
Many thanks.
Hi ive an eberspacher d2 airtronic heater ive just replaced combi sensor but its still blowing constant cold air wont perform any start up procedure.. Any ideas? Regards alan
i have a erberpacher fitted to my vw , fan is working , glow plugs working ? no deisel gettin through from tank , tryed a blow back down pipe ,still no deisel , please help

Hi
I am trying to find fault codes on my 7 day timer. I press and hold the start button and the word 'data' shows for a few seconds then the display goes back to the normal 'off' display. I was expecting to see an error ccde, (or zero). Is this expected behaviour?
Hi,

my eberspacher D3l goes through all the start up sequences and gives out good heat but the exhaust noise has changed? It now rises and falls as though it is being activated by a bellows (for want of a better description). It used to be a constant "whooshing" noise. The "wick", combustion air blower and all felt rings, gaskets and sealing ring have recently been replaced. Do you think it could it be a fuel problem? Possibly air in fuel line?
Hi. I have an airtronic D2 12v on my boat. I was working v well yesterday(the boat was on shore power to re charge the batteries). today the 7 day display works but nothing hapens when i try to turn on the heating. I checked the fuses and the 20amp fuse was blown. I tried a new fuse - blew again on turning on the power to the heating system. Any ideas? thanks. Denis
hi, I recently bought a used d2 airtronic 24volt heater, installed it and all was ok, went through all the actions at medium settings, I turned the dial to max and went about my business cutting the lawn etc, checked the heater after 40 minutes the van was warm, the pump was stopped and the fan running on med, i took it had gone off due to reaching temp so i turned it off at controller, immediatly the fan increased and after 2 or 3 minutes it shut down, all good, i re started it after 5 mins but the fan rotated one revolution at low speed and stopped, nothing else. i switched it off and removed the 24volts for 48 hours, tried again but nothing at all apart from a relay click, any info would be great, thanks Dan.
Hi I have just fitted a eberspacher D2 it runs for about 5 minuits then pump stops and goes into cool down mode even though its a new pump ,have you any ideas
Hi check out the advice centre www.pfjones.co.uk/eberspacher-airtronic-fault-finding-guide.html on the pink navigation bar at the top of the page may help Brian
Ask Question